Consumption
Energy & Steam
Measure the honest number. Then find out what is moving it.
Steam per tonne of feed is what most plants quote, and it moves every time the feed changes. Steam per tonne of acid gas removed is normalised to the duty the unit is actually doing. The platform trends both — and when the honest one drifts, it names the fault behind it.
Steam per tonne of feed and steam per tonne of acid gas are trended side by side. When the feed sours up the first gets worse while the plant is doing more work, not less. Ten signals are then ranked against the honest ratio — circulation, lean temperature, acid gas load, reboiler temperature, reflux ratio and the rest — so the strongest bar tells you where to look first.
02
Excess steam is a symptom with named causes
Lean/rich exchanger fouling means the rich amine arrives colder and the reboiler makes up the difference, quietly, for months. Reboiler scaling means more steam for the same duty. Under-stripping and over-duty are a two-sided error the engine tells apart. Excess energy is one of six costed consequences, carrying a figure per hour.
03
Bad steam, not more steam
Reboiler heat input is read with the desuperheat trim and the supply pressure alongside it. That is what separates a reboiler that genuinely needs more duty from a utility system delivering superheated or under-pressure steam — a supply problem no amount of valve opening will fix.
04
The 127 °C line
Reboiler temperatures are tracked against the point where thermal degradation of MDEA accelerates. Energy pushed in above that buys stripping and pays for it in solvent life, which the platform prices as a separate consequence rather than leaving it out of the sum.
Where to see it
Every number here is on a screen you can open.
Nothing on this page is a calculation done for a brochure. Each line below names the tool and the view that shows it, running on real operating history.
Tool
Discover → Regeneration & energy → Energy efficiency
Ratios
Steam per tonne of feed · steam per tonne of acid gas · reflux ratio
Driver ranking
10 signals scored against steam per tonne of acid gas
Cost
Detect → the excess energy consequence, with a figure per hour
Forecast
Prognose → fouling channels fitted over 3 days, projected 6 h
Where the tool stops and you start
The platform finds where steam is being wasted, names the fault behind it and prices it per hour. It does not move a setpoint and it does not write to your control system — by design, and we do not intend to change that. Every number here can be checked against your own steam meter, which is the point: an efficiency figure you cannot verify is worth nothing in a review.